ARCHITECT "I" System - i2000SR Processing Module - Class 4

Health Canada published a recall notice for ARCHITECT "I" System - i2000SR Processing Module - Class 4 on 16 Oct 2026. It is one of 326 notices of this kind from Health Canada since 2 Apr 2026 in AreaZine's record.

Recall

The recall notice

Issued by
Health Canada
Issued
16 Oct 2026
Recall type
Health product recall
Companies
Abbott Laboratories · 1915 Hurd Drive, Irving, Texas, United States, 75038
Official source
Health Canada: the notice at its source

The latest from Health CanadaEvery warning and recall in Canada

Source: Health Canada: the notice at its source. AreaZine rebuilds this page from the agency's record; the agency's page is the one to act on. Contains information licensed under the Open Government Licence – Canada.

The notice as issued

Issue: An issue has been identified with the 5 Amp (5A) diode used in the Induction Heater (IH) Control Module on the ARCHITECT i2000SR IH Kit (optional hardware). The diode may be exposed to current exceeding its specified rating, potentially resulting in component failure. Failure could cause localized electrical arcing, circuit board damage, and smoke generation. Only ARCHITECT i2000SR Processing Modules with an Induction Heater (IH) Control Module are impacted.The IH Control Module housing is classified as a fire enclosure in accordance with International Electrotechnical Commission (IEC) 61010-1 and is designed to contain thermal events. Protective features include flame-retardant circuit board material and a metal fire-rated enclosure, which help prevent propagation beyond the module. In all failures, the observed damage remained contained within the IH Control Module, and no injuries or property damage have been reported.There is potential for operator injury and property damage due to smoke, burn, hot surfaces, etc. caused by the excess current on the diode. There have been no occurrences of fire and smoke leading to property damage and no reported occurrences of operator injury for this issue. Additional information Details Original published date: 2026-10-16 Affected products: Affected products Lot or serial number Model or catalogue number ARCHITECT "I" System - i2000SR Processing Module - Class 4 ISR64041 03M74-02 Issue

Source: Health Canada: the notice at its source. The text is the agency's, unedited. Contains information licensed under the Open Government Licence – Canada.